Skip to content Skip to footer

EP3300 TLV Series (AC:110/220V 1-3KW)

Low Frequency Pure Sine Wave Split Phase Inverter Charger 1~3KW | AC110V/220V | MPPT 80A | WiFi | BAT-CAN

This split phase inverter EP3300 TLV series, capacity from 1KW-3KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 220V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charge controller to build a solar home system, take use of sunshine freely and save electricity bills.

Model Certification & Standards
EP33-1012/1024/1512/1524/2012/2024/3024/3048 TLV CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

Description

■ Pure sine wave output

■ 3 steps charging

■ Overlord and short- circuit protection

■ Set charging voltage/charging current

■ Power-save mode

■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V

■ Inverter voltage can be set to 100/110/120V

■ Inverter frequency can be set to 50/60Hz

■ Acid or Lithium select

■ WIFI monitoring function (optional)

■ With BMS lithium battery communication function (CAN port)

MODEL EP33-1012 TLV EP33-1024 TLV EP33-1512 TLV EP33-1524 TLV EP33-2012 TLV EP33-2024 TLV EP33-3024 TLV EP33-3048 TLV
INVERTER OUTPUT
Rated power 1KW 1.5KW 2KW 3KW
Surge rating 3000VA 4500VA 6000VA 9000VA
Capable of starting electric motor 1P 1P 1.5P 1.5P
Power factor 1
Wave form Pure sine wave / Same as input wave form (bypass mode)
Output voltage RMS 100V / 110V / 120VAC (200V / 220V / 240VAC) ±10%
Output frequency 50Hz or 60Hz (±0.3Hz) (can be set)
Overload protection Breaker + software protection
Output short circuit Breaker + software protection
Inverter efficiency (peak) >85%
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
BATTERY
Battery voltage 12VDC / 24VDC 24VDC / 48VDC
Minimum start voltage (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage cut off 10V/ 10.5V/ 11V/ 11.5V/ 12V  for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm (12-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Save mode Load ≤50±20W(120V)/100±20W(220V)
AC INPUT MODE
Input waveform Pure sine wave
Nominal input voltage 200Vac / 220Vac / 240Vac
Max input voltage 270Vac MAX
Input frequency 50Hz / 60Hz (auto sensing)
Efficiency (AC mode) >95% (load, full battery)
Transfer time AC to DC 15ms(max)
Transfer time DC to AC 15ms(max)
CHARGE MODE
Boost voltage 14.1V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
Float voltage 13.5V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
12V 30A 45A 60A /
24V 20A 25A 30A 40A
48V / / / 20A
Min charge current 10A. Change by every 5A
DIMENSIONS
Machine Dimension (W*H*D) 443*359.2*188mm
Package Dimension (W*H*D) 598*457*308mm
Warranty 1 year
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)
Headquarters

Address: Building 8. No. 115. zhangcha 1st road.South China power innovation Science Park, Foshan, China

Get In Touch
+86 755 83657660 (Europe)
+86 755 83651325/+86 757 82629306 (Americas)
MUST ENERGY © 2024. All Rights Reserved.