Description
■ Lithium Battery Modular 5120Wh/10240Wh
■ Self-consumption and feed-back to the grid
■ Multiple Working Mode: Energy storage mode, load priority mode, power selling mode,and a high-efficiency mode (six time periods are provided for setting different modes to achieve peak-shaving and valley-filling, maximizing economic benefits)
■ Inside BMS,support to be charged and discharged according to bms requirements
■ Support to connect with generator
■ Automatic line-to-battery switch over
Model | HBP11-3648 HP | HBP11-4048 HP | HBP11-4648 HP | HBP11-5048 HP | HBP11-6048 HP |
Nominal Battery System Voltage | 48VDC | ||||
INVERTER OUTPUT | |||||
Rated Power | 3600W | 4000W | 4600W | 5000W | 6000W |
Waveform | Pure Sine Wave | ||||
Nominal Output Voltage RMS | 220~240Vac | ||||
Output Voltage Regulation | +10/-18% | ||||
Output Frequency | 50Hz/60Hz | ||||
Inverter Efficiency (Peak) | 97% | ||||
Typical Transfer Time | 10ms, 15ms max | ||||
AC INPUT | |||||
Voltage | 230VAC | ||||
Voltage Range | 180~280Vac | ||||
Frequency Range | 47.5~52.5Hz / 57.5~62.5Hz | ||||
BATTERY | |||||
Note: Below Parameters base on one LiFePO4 Lithium Battery Modular | |||||
Battery | 51.2VDC 100AH 5120/10240Wh | ||||
Low Battery Cutoff | 44VDC | ||||
Low Battery Alarm | 46VDC | ||||
Low Battery Voltage Recover | 48VDC | ||||
High Voltage Alarm | 58.5VDC | ||||
High Battery Voltage Recover | 57.5VDC | ||||
SOLAR CHARGER & AC CHARGER | |||||
Maximum PV Array Open Circuit Voltage | 500VDC | ||||
PV Array MPPT Voltage Range | 120~500VDC | ||||
Maximum Solar Charge Current | 75A | 85A | 95A | 100A | 125A |
Maximum AC Charge Current | 75A | 85A | 95A | 100A | 125A |
Maximum Charge Current | 75A | 85A | 95A | 100A | 125A |
Charger Voltage | 56.5VDC | 56.5VDC | 56.5VDC | 56.5VDC | 56.5VDC |
Charging Current | 75A | 85A | 95A | 100A | 100A |
Charging Time | 2-3 hours | 2-3 hours | 1-2 hours | 1-2 hours | 1-2 hours |
Overcharge Protection S.D. | 60VDC | 60VDC | 60VDC | 60VDC | 60VDC |
OUTPUT | |||||
AC Output | 230Vac (Terminal) | ||||
BYPASS & PROTECTION | |||||
Nominal Input Frequency | 50Hz or 60Hz | ||||
Circuit breaker | FUSE | ||||
Output Short Circuit Protection | 55A | 60A | 70A | 80A | 90A |
Max Bypass Current | 16A | 18A | 21A | 23A | 27A |
MECHANICAL SPECIFICATIONS | |||||
Dimensions (W*D*H) (mm) | 5120WH: 492*220*1191mm / 10240WH: 492*220*1727mm | ||||
Shipping Dimensions (W*D*H) (mm) | Inventer:830*590*316mm / Battery:615*555*295mm | ||||
OTHER | |||||
Operating Temperature Range | -15℃ to 40℃ | ||||
Ingress protection rating | IP66 | ||||
Audible Noise | 60dB MAX | ||||
Display | LED+LCD | ||||
Standard Warranty | 2 year |