Skip to content Skip to footer

PC1800F Series (60/80/100A)

MPPT Solar Charge Controller

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.

Model Certification & Standards
PC18-6015F/8015F/10015F CE-EMC+LVD(EN6100-6-3:2007+A1:2011, EN6100-6-1:2019+EN IEC62109-1:2010)
PC18-6015F/8015F/10015F UKCA(BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)
Category: Tag: Product ID: 26007

Description

Features:

• LCD display , easy to operate on LCD screen

• Multi stage charging (3-stage charging , parallel charging and equalized charging function)

• BTS – Battery remote temperature sensor terminal

• Enable to charge Li-thium, Gel , lead-acid battery

• With RS485 & USB communication port

• Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit

Specification:

MODEL PC18-6025F PC18-8025F PC18-10025F
Nominal Battery System Voltage 12V / 24V / 48VDC (Auto detection); 36V (Setting)
CONTROLLER INPUT
Battery Voltage 12V / 24V / 36V / 48V
Maximum Solar Input Voltage 12V (VBAT) 100V
24V (VBAT) 245V
36V (VBAT) 245V
48V (VBAT) 245V
PV Array MPPT Voltage Range 12V (VBAT) 15-95V
24V (VBAT) 30~230V
36V (VBAT) 45~230V
48V (VBAT) 60~230V
Maximum Input Power 12V (VBAT) 940W 1250W 1560W
24V (VBAT) 1880W 2500W 3120W
36V (VBAT) 2820W 3750W 4680W
48V (VBAT) 3760W 5000W 6250W
BATTERY
Flooded Battery Absorption Stage 14.2V / 28.4V / 42.6V / 56.8V
Float Stage 13.7V / 27.4V / 41.1V / 54.8V
AGM (Default) Absorption Stage 14.4V / 28.8V / 43.2V / 57.6V
Float Stage 13.7V / 27.4V / 41.1V / 54.8V
Over-charging Voltage 15.5V / 30.0V / 45.0V / 60.0V
Over-charging Comeback Voltage 14.5V / 29.5V / 44.5V / 59.0V
Battery Defect Voltage 10.0V / 17.0V / 25.5V / 34.0V
Temperature Compensation Conefficient -5mv / ℃ /cell (25℃ vef)
Peak Conversion Efficiency 98% (MPPT Efficiency 99%)
Maximum Battery Current 60A 80A 100A
Maximum DC load current / / 100A
Max Charging Current 60amps continuous @ 40℃ ambient 80amps continuous @ 40℃ ambient 100amps continuous @ 40℃ ambient
DISPLAY & PROTECTION
Protections Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D) 306.6*163.6*94.9mm 284*165*97mm
Package Dimension (W*H*D) / /
G.W 3kg 4kg
N.W /
OTHER
Mounting Wall mount
Environmental Rating Indoor
Enclosure IP20
Radiating Mode Fan cooling
Operation Temperature Range -10~55℃
Ambient Humidity 0~90% relative humidity (non-condensing)
Altiude ≤3000m