This model PH3000 Three-phase is a flexible and intelligent energy storage inverter which utilizes solar power, utility power, and battery power source to supply continuous power. This is a multi-functional hybrid inverter which can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner. The system generates electricity when it has sufficient sunshine, supplying power to your home and feeding any surplus power back to the Grid.

Model Certification & Standards
PH30-12048T, PH30-12048S CE-EMC+LVD(EN6100-6-4: 2007, EN6100-6-2:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
PH30-10048T/12048T, PH30-10048S/12048S CE-LVD(IEC62109-1:2010, EN IEC62109-2:2011)

Description

Features:

• Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.)

• Built-in MPPT 180A solar charge controller

• MPPT Efficiency max 98%

• Combining solar system, AC utility, and battery power source to supply continuous power

• Multiple operations: basic Grid-tie, Off-Grid, Grid-Interactive

• Support CAN, RS485 monitoring function

Specification:

MODEL PH30-10048-T PH30-12048-T
Nominal Battery System Voltage 48VDC
INVERTER OUTPUT
Rated output power 10000W 12000W
Output wave Pure sine wave
Nominal output voltage 230 VAC (P-N) / 400 VAC (P-P)
Nominal output current 14.3A per phase 17.4A per phase
Nominal output frequency 50 Hz / 60 Hz
Rate of wave distortion(THD)(Linearity loads) Off grid≤2%; Grid discharge ≤3%; Grid charge ≤3%
Peak efficiency ≥93%
Overload capability 100%<load≤110%,30 minutes; 110%<load≤125%,1 minutes; 125%<load≤150%,30 seconds; load<150%,10 seconds; Short circuit,5 seconds
AC INPUT
AC input maximum current 26.0A per phase 34.8A per phase
Nominal frequency 50Hz / 60Hz
Acceptable input voltage range Defaults  186Vac ~253Vac per phase;Narrow  174Vac ~272Vac per phase; Wide 95Vac ~272Vac per phase
BATTERY
Type of Battery Lithium battery or lead-acid battery
Nominal Voltage 48VDC
Low Voltage Protection Point Charger 34.0VDC; Inverter 40.0VDC
Absorption Voltage 50.0VDC
Refloat Voltage 54.8VDC
Float Voltage 57.2VDC
SOLAR CHARGER & AC CHARGER
PV Open Circuit Voltage 145VDC
Max Solar Charging Current 60A per channel
Max AC Charging Current 60A per phase 80A per phase
Max Charging Current 120A per phase 140A per phase
MECHANICAL SPECIFICATIONS
Mounting Vertical
Machine Dimension, W*H*D(mm) 392*828*629
Package Dimensions (W*H*D)(mm) 513*1031*700
Net Weight (kg) 133 140
Gross Weight (kg) 128 160
OTHER
Communication terminal RS485 / CAN bus
Operation Temperature Range 0℃ ~ +50℃
Environmental Protection Rating IP20
Ambient humidity 0 — 90% relative humidity (non-condensing)
Altitude ≤2000m