Skip to content Skip to footer

PH5900 Series (3-6KW)

High Frequency On Grid Solar Inverter 3~6KW | Single Phase | MPPT 40~550V

PH5900 series PV inverters take full account of the needs of end customers, with excellent performance at the same time, use LED as inverter status display, effectively improve product life. Using DSP digital control,could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.

Model Certification & Standards
PH59-3000,PH59-3600M/PH59-4200M/PH59-4600M/PH59-5000M/PH59-6000M CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
IEC60529; IP66
EN50549-1:2019
RD1699, UNE206006:2011, UNE206007: 2013
Poland Type A(NC RfG:2016, PSE:2018, PTPiREE:2021)
G98, G99

Description

Features:

• High Frequency On Grid Solar Inverter

• MPPT efficiency up to 99.50%

• Multiple communications: USB,WIFI etc

• Monitoring inverters freely via mobile phonese APP

• Fanless low-noise design

• IP66 water-proof and dust-proof

Specification:

MODEL PH59- 3000M PH59- 3600M PH59- 4200M PH59- 4600M PH59- 5000M PH59- 6000M
RATED POWER 3000W 3600W 4200W 4600W 5000W 6000W
PV INPUT(DC)
Maximum recommended DC power 3900W 4700W 5200W 5980W 6500W 7800W
Nominal DC operating voltage 360V
Maximum DC voltage 550V
Start voltage 50V
MPPT voltage range 40~550V
Maximum input current 16A/16A
No.of MPP tracker 2/1
DC connection H4/MC4
GRID OUTPUT(AC)
Nominal AC output power 3000W 3600W 4200W 4600W 5000W 6000W
Maximum AC output power 3000VA 3600VA 4200VA 4600VA 5000VA 6000VA
AC grid frequency; range 50/60Hz ±5Hz
Maximum output current 13.6A 16A 19A 20.9A 22.7A 27.2A
AC nominal voltage 220V/230V/240V
AC voltage range 180-280V
Total harmonic distortion (THDi) <3%
Rate power factor 1
Displacement power factor 0.8 leading ~ 0.8 lagging
AC grid connection type L+N+PE
EFFICIENCY
Maximum efficiency 98.0% 98.0% 98.1% 98.1% 98.2% 98.2%
Euro-efficiency 96.8% 96.8% 97.0% 97.0% 97.2% 97.2%
MPPT efficiency 99.5%
Self-Consumption night <1W
PROTECTION DEVICES
Output over current protection Yes
Output AC overvoltage protection Yes
DC reverse polarity protection Yes
DC switch Yes
Ground fault monitoring Yes
Integrated all-pole sensitive leakage current monitoring unit Yes
PHYSICAL
Machine Dimension (W*H*D) 402*378*195mm
G.W 11kg
INTERFACE
DC connection H4/MC4
AC connection Connector
Display LED
Communication interfaces WIFI/RS485/GPRS(opt)
ENVIRONMENT
Ingress protection rating IP66
Humidity 0-100%
Operating temperature range -25℃ ~+60℃ With derating above 45℃
Cooling concept Natural
Noise emission(typical)[dB] ≤35dB(A)
Self-consumption night <1W
Topology Transformerless
Altitude 4000m
OTHERS
Topology transformerless
Warranty Standard 5years/10 years(opt.)
CERTIFICATION & STANDARDS
CE-EMC+LVD(EN6100-6-3, 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

IEC60529; EN50549-1:2019; RD1699, UNE206006:2011, UNE206007:2013

Poland Type A (NC RfG:2016, PSE:2018, PTPiREE:2021)

G98, G99

Headquarters

Address: Building 8. No. 115. zhangcha 1st road.South China power innovation Science Park, Foshan, China

Get In Touch
+86 755 83657660 (Europe)
+86 755 83651325/+86 757 82629306 (Americas)
MUST ENERGY © 2024. All Rights Reserved.