Skip to content Skip to footer

PV1500 LV Series (AC:120V 1500VA)

Off Grid Solar Inverter 1500VA | AC 120V | PV 100V

It is a cost efective, inteligent solar inverter which accepts Solar & Utility input at the same fime. The comprehensive lCD display ofers user-conigurable and easy-accessible buton adjustment such as batery charging curent, AC/solar charger priority and DC priority,.When battery voltage islow,it will automatically switch to AC grid to supply continuous power to the loads.

Description

■ Built-in 30A MPPT Solar Charge Controller

■ 10A or 15A standard charging current from utility AC

■ 2 Output ports for DC load

■ AC/solar priority for charging via MFD

■ Different charging mode for different kinds of batteries

■ Overload & short-circuit protection, Battery reverse polarity protection, Deep discharge protection

■ Auto restart while AC/solar is recovering Adjustable solar and utilitycharging current

■ Support fast max charging current setting

■ Support two kinds of batteries: LiFePO4 Lithium Battery Packand Lead-acid Battery

■ Automatic activate lithium battery pack which is be over discharged no output when AC input is OK

MODEL PV15-1512 LV PV15-1524 LV
Nominal Battery System Voltage 12VDC 24VDC
NVERTER OUTPUT
Rated Power 1500VA/ 1000W
Waveform Pure Sine Wave
Nominal Output Voltage RMS 120V
Output Voltage Regulation +10/-18%
Output Frequency 50Hz / 60Hz ± 1Hz
Inverter Efficiency (Peak) >90%
Line Mode Efficiency >95%
Typical Transfer Time Typical < 10ms , 15ms max
AC INPUT
Voltage 120VAC
Voltage Range 88 ~ 144VAC ± 3%
Frequency Range 45 ~ 65Hz ± 2Hz
BATTERY
Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack – 12V(4 Series) 24V(8 Series)
Nominal Input Voltage 12VDC 24VDC
Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)
Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
High Battery Voltage Recover 14.5VDC(PB) 14.3VDC(LI) 29.0VDC(PB) 28.6VDC(LI)
High Battery Voltage Cutoff 15.0VDC(PB) 14.8VDC(LI) 30.0VDC(PB) 29.6VDC(LI)
SOLAR CHARGER & AC CHARGER
Charger Voltage boost 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Charger Voltage float 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
Maximum PV Charge Current 40A (max)
Maximum PV Array Power 600W 1200W
MPPT Operating Voltage Range 14 ~ 75VDC 28 ~ 75VDC
Maximum PV Array Open Voltage 100VDC
Maximum Efficiency > 95%
Standby Power Consumption < 2W
AC Charging Current 20A (Can be set)
Maximum Charge Current AC+PV 60A (Can be set)
BYPASS & PROTECTION
Overload Protection (SMPS Load) FUSE
Output Short Circuit Protection FUSE
Bypass Fuse Rating 15A
Max Bypass Current 15A
Battery Fuse Current 50A x 3 50A x 2
OTHER
Operation Temperature Range 0℃ to 40℃
Audible Noise 50dB MAX
Display LED+LCD
DIMENSIONS
Machine Dimension (W*H*D) 320*267*96mm
N.W 4.5kg
Headquarters

Address: Building 8. No. 115. zhangcha 1st road.South China power innovation Science Park, Foshan, China

Get In Touch
+86 755 83657660 (Europe)
+86 755 83651325/+86 757 82629306 (Americas)
MUST ENERGY © 2024. All Rights Reserved.