Skip to content Skip to footer

EP3000 PLUS Series (4-6KW)

Low Frequency Power Inverter/Charger 4~6kW | 230V | WIFI | BAT-CAN

EP3000 PLUS series is a very economical pure sine wave inverter, with AC charger from 20A to 60A; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower . With pure copper transformer, it enables inverter to operate with all kinds of home appliances.

Model Certification & Standards
EP30-4024/4048/5048/6048PLUS CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
Category: Tag: Product ID: 26230

Description

■ 3 Steps charging

■ Overload and short-circuit protection

■ Set charging voltage/charging current.

■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5V/ 12V

■ Power-save mode

■ Set utility priority/ Battery priority

■ Set utility input wide/narrow range

■ Inverter voltage can be set to 220V:220V/230V/240V

■ Inverter frequency can be set to 50/60Hz

■ Set utility charging on/off switch

■ Acid or Lituium select

■ WIFI remote monitoring (optional)

■ With BMS lithium battery communication function (CAN port)

MODEL EP30-4024 PLUS EP30-4048 PLUS EP30-5048 PLUS EP30-6048 PLUS
Nominal Battery System Voltage 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 4KW 5KW 6KW
Surge Rating 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 2HP 3HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 220V / 230V / 240VAC ±10% (RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 155~265VAC(For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V/ 10.5V/ 11V/ 11.5/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm (12-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤100±20W(220V)
CHARGER
Output Voltage Depends on battery type
Charge AC Input Breaker Rating (230V) 4-6K/50A
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current 60A 30A 35A 40A
BYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
AC Input Breaker 4-6K/50A
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Machine Dimension (W*H*D) 531*305*202mm
Package Dimension (W*H*D) 686*400*319mm
N.W 31kg 29.5kg 30.9kg 34.5kg
G.W 32.5kg 31kg 32.4kg 36kg
OTHER
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 1 year, 2 or 3 years optional (IP20)
CERTIFICATION & STANDARDS
CE-EMC+LVD(EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2) IEC60950-1 A1+A2; CE-EMC+LVD,EN62040-2,EN62040-1
Headquarters

Address: Building 8. No. 115. zhangcha 1st road.South China power innovation Science Park, Foshan, China

Get In Touch
+86 755 83657660 (Europe)
+86 755 83651325/+86 757 82629306 (Americas)
MUST ENERGY © 2024. All Rights Reserved.