Description
■ 100% unbalanced output, each phase max. output up to 50% rated power
■ Max. 6 pcs parallel for on-grid and off-grid operation
■ AC couple to retrofifit existing solar system
■ Support multiple batteries parallel
■ Max. charging/discharging current of 240A
■ Support storing energy from diesel generator
■ 48V low voltage battery, transformer isolation design
■ IP65 water-proof and dust-proof
■ “Time of use” function: a maximum of 6 time segments can be set
■ Wifi monitoring
MODEL | PH1100-8KL3-EU | PH1100-10KL3-EU | PH1100-12KL3-EU |
Rated power | 8000W | 10000W | 12000W |
BATTERY INPUT DATA | |||
Battery type | Lead-acid battery / Lithium battery | ||
Battery voltage | 48V | ||
Battery voltage range | 40~60V | ||
Charging curve | 3-stage adaptive with maintenance/Equalization | ||
Charging Strategy for Li-lon Battery | Self-adaption to BMS | ||
Over-current protection/ Over-temperature protection | Yes / Yes | ||
Maximum charging/discharging power | 8000W | 10000W | 12000W |
Maximum charging/discharging current | 190A | 210A | 240A |
PV STRING INPUT DATA | |||
Max. DC Input Power | 10400W | 13000W | 15600W |
Rated PV Input Voltage | 550V | ||
Maximum DC voltage | 800V | ||
Start-up Voltage | 160V | ||
Minimum voltage for grid connection | 310V | ||
Full Load DC Voltage Range | 350-650V | ||
Enter high voltage error recovery point | 800V | ||
MPPT voltage range | 200~650V | ||
Maximum input current | 13A/13A | 26A/13A | 26A/13A |
No.of MPP Trackers | 2 | ||
No.of Strings per MPP Tracker | 1+1 | 2+1 | 2+1 |
AC OUTPUT DATA | |||
Rated AC Output Power | 8000W | 10000W | 12000W |
Max AC Output Power | 8800W | 11000W | 13200W |
AC Output Rated Current | 12.1/11.6A | 15.2/14.5A | 18.2/17.4A |
Max AC Output Current | 13.4/12.8A | 16.7/15.9A | 20/19.1A |
Max. Three-phase Unbalanced Output Current | 18.2/17.4A | 22.7/21.7A | 27.3/26.1A |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Rated Input/Output Voltage | 220/380,230/400Vac | ||
Rated Input/Output Grid Frequency/Range | 50/60;45~55/55-65 | ||
Grid Type | Three Phase | ||
Total Harmonics Current Distortion (THDi) | <3% (of nominal power) | ||
DC Current Injection | <0.5% In | ||
EFFICIENCY | |||
Max. Efficiency | ≥97.5% | ||
Euro Efficiency | 97.0% | ||
PROTECTION | |||
Integrated | PV Arc Fault Detection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection | ||
Surge Protection | DC Type III/AC Type III | ||
Overvoltage Category | DC Type II/AC Type III | ||
GENERAL DATA | |||
Operating Temperature Range (°C) | -20°C to +60°C, >45°C Derating | ||
Cooling | Smart cooling | ||
Noise (dB) | ≤55dB | ||
Communication with BMS | Wi-Fi/USB/GPRS/RS485/CAN | ||
Weight (kg) | 35 | ||
Cabinet Size (WxHxD mm) | 444*654.2*259.2 | ||
Protection Degree | IP65 | ||
Installation Style | Wall-mounted | ||
Warranty | 5 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | ||
CERTIFICATION & STANDARDS | |||
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC 62109-1, EN IEC 62109-2); CE-LVD(EN 62477-1) ; IEC 60529; EN50549-1;
Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021) C10/C11; UNE217001-2020; UNE217002-2020, NTS-631 (Type A); G98+G99 |